CNC · Lateral
EPS
EP 11S · EP 13S · ½" Tool Interface · Servo-ventilated
2.2–5.2 kW
Power range
10,000 rpm
Max speed
5.5–11 Nm
Torque
Servo-ventilated½"ManualIP55
What it's built for
Where the EPS fits
Sustained duty without a water circuit
Servo-ventilation drives the fan independently of spindle speed, so the compact spindle holds its rating through long runs where the air-cooled EP would lose cooling, and it does so without plumbing a water circuit for the motor.
Wet cutting at the edge
The contactless rotating water joint feeds coolant through the tool without seals to service, on the same bored-shaft body as the base EP. For fine, continuous work where coolant has to reach the cut cleanly.
Same ½" mount, cooling matched to duty
Sits between the air-cooled EP and the water-cooled EP 11-RA on one ½" compact body, so the head is designed once and the cooling is specified to the process.
Lighter or intermittent duty needs no fan at all: the air-cooled EP shares the mount. For continuous wet duty, EP 11-RA adds full water cooling. Use the motor selector to compare.
Technical data · Catalogue ed. 2024.09
Full specifications
Technical specifications
Power (min / max)
2.2–5.2 kWTorque
5.5–11 NmMax speed
10,000 rpmTool attachment
½"Motor type
AC InductionCooling
Servo-ventilatedLubrication
Maintenance-free bearingsTool change
ManualIP rating
IP55Mount type
LateralStandard features
Compact design · Bored shaft for through-tool water passage · Contactless rotating water jointVariant table
| Ref. | kW | Cv | Nm | A @400V | rpm nom | F nom Hz | rpm max | F max Hz | Poles | kg |
| EP11S (50Hz) | 2.2 | 3 | 7.5 | 5.2 | 2,790 | 50 | 10,000 | 166 | 2 | 20 |
| EP11S (100Hz) | 3.3 | 4.5 | 5.5 | 7.5 | 5,780 | 100 | 10,000 | 166 | 2 | 20 |
| EP13S A (50Hz) | 2.4 | 3.2 | 8 | 5.4 | 2,830 | 50 | 10,000 | 166 | 2 | 25 |
| EP13S A (100Hz) | 4 | 5.5 | 6.7 | 8.6 | 5,820 | 100 | 10,000 | 166 | 2 | 25 |
| EP13S B (50Hz) | 3.3 | 4.5 | 11 | 8 | 2,850 | 50 | 10,000 | 166 | 2 | 30 |
| EP13S B (100Hz) | 5.2 | 7 | 8.7 | 10.8 | 5,840 | 100 | 10,000 | 166 | 2 | 30 |
Standard configurations shown. Other pole counts and power ratings available on request. Performance data obtained by numerical simulation.
Standard & Optional
Features & Options
Standard features
- Compact design
- Bored shaft for through-tool water passage
- Contactless rotating water joint
- Inverter-duty insulation system
Options & Accessories
- High-speed bearings
- Custom shaft (ER DIN6499 or Whistle notch)
Upgrade path
Same mount, more capability
All families in this path share the same mount geometry. Design the machine head for the highest capability you might ever need: start with the base family and upgrade without structural rework. Use the motor selector to compare families.
Full technical datasheet in the VEM library